TID response of various field programmable gate arrays and memory devices

Jean-Marc Armani 1 J.L. Leray 2 R. Gaillard V. Iluta 3 
1 LFIC - Laboratoire Fiabilité et Intégration de Capteurs
DM2I - Département Métrologie Instrumentation & Information : DRT/LIST/DM2I
Abstract : The Total Ionizing Dose (TID) tolerance of some FPGAs and memory devices has been evaluated. Two FPGAs and five memories of various types and technologies have been irradiated. Results show that the total dose tolerance of the tested FPGAs is around 200 Gy. The SRAM is the most tolerant device with a failure dose level over 2.4 kGy. Two Flash memories were still well-functioning after 1 kGy.
Complete list of metadata

https://hal-cea.archives-ouvertes.fr/cea-01839850
Contributor : Léna Le Roy Connect in order to contact the contributor
Submitted on : Thursday, December 23, 2021 - 1:24:24 PM
Last modification on : Thursday, February 17, 2022 - 10:08:06 AM

File

article_JeanMarcArmani_RADECS-...
Files produced by the author(s)

Identifiers

Citation

Jean-Marc Armani, J.L. Leray, R. Gaillard, V. Iluta. TID response of various field programmable gate arrays and memory devices. 2015 15th European Conference on Radiation and Its Effects on Components and Systems (RADECS), Sep 2015, Moscow, Russia. pp.7365686, ⟨10.1109/RADECS.2015.7365686⟩. ⟨cea-01839850⟩