TID response of various field programmable gate arrays and memory devices - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Access content directly
Conference Papers Year : 2015

TID response of various field programmable gate arrays and memory devices

J.L. Leray
  • Function : Author
V. Iluta
  • Function : Author

Abstract

The Total Ionizing Dose (TID) tolerance of some FPGAs and memory devices has been evaluated. Two FPGAs and five memories of various types and technologies have been irradiated. Results show that the total dose tolerance of the tested FPGAs is around 200 Gy. The SRAM is the most tolerant device with a failure dose level over 2.4 kGy. Two Flash memories were still well-functioning after 1 kGy.
Fichier principal
Vignette du fichier
article_JeanMarcArmani_RADECS-2015_final.pdf (368.38 Ko) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

cea-01839850 , version 1 (23-12-2021)

Identifiers

Cite

Jean-Marc Armani, J.L. Leray, Rémi Gaillard, V. Iluta. TID response of various field programmable gate arrays and memory devices. 2015 15th European Conference on Radiation and Its Effects on Components and Systems (RADECS), Sep 2015, Moscow, Russia. pp.7365686, ⟨10.1109/RADECS.2015.7365686⟩. ⟨cea-01839850⟩