Résumé

In order to improve the safety of nuclear power plant, loss-of-coolant accident experiments are implemented in research reactor. In this framework, we develop an optical pyrometry device to measure surface temperature (700-1200°C) of Zircaloy cladding without contact. The whole set-up of the simplified device (under air, without radiation) and the measurement procedure including data treatment based on bichromatic pyrometry are presented, as well as results for various temperature levels. Temperature retrieval based on the hypothesis of emissivity ratio equal to a constant, is scanned over a large wavelength range. A rather constant surface temperature is obtained on the spectral range of measurement, confirming the relevancy of emissivity hypothesis. Differences between this non-contact temperature measurement and a complementary thermocouple temperature measurement are also discussed.