Status of the SPIRAL 2 LINAC cryogenic system

Résumé

SPIRAL 2 is a state of the art superconducting linear accelerator expected to deliver some of the highest intensity rare isotope beams on earth. The project has been in development/design, fabrication and installation for over 10 years and is now reaching its final critical stages before commissioning. One of its most critical parts is a cryoplant and a cryodistribution system that feed the heart of the accelerator with the necessary refrigeration power and allow the required pressure and thermal regulation to be achieved and maintained in a reliable way. This paper summarises the latest updates of the cryogenic system before the first cool down trials. It also plots the strategies and R&D efforts undertaken to tackle some of the challenges that SPIRAL 2 is expected to face.
Fichier non déposé

Dates et versions

hal-01582414 , version 1 (06-09-2017)

Identifiants

Citer

A. Ghribi, P.-E. Bernaudin, A. Vassal, F. Bonne. Status of the SPIRAL 2 LINAC cryogenic system. Cryogenics, 2017, 85, pp.44-50. ⟨10.1016/j.cryogenics.2017.05.003⟩. ⟨hal-01582414⟩