Nd, Am and Cm isotopic measurement after simultaneous separation in transmutation irradiated samples - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Access content directly
Journal Articles Journal of Analytical Atomic Spectrometry Year : 2021

Nd, Am and Cm isotopic measurement after simultaneous separation in transmutation irradiated samples

Abstract

In this work, a High-Performance Liquid Chromatography (HPLC) separation followed by Thermal Ionization Mass spectrometry (TIMS) measurements was optimized to measure Am, Cm and Nd isotope ratios in irradiated samples. The method validation was performed on a natural Nd standard (JNdi-1 reference material). The literature JNdi-1 reference values are calculated using a conventional internal normalization. However, in nuclear science, such normalization is not possible as no isotope ratio can be considered as a reference. Measurements were compared to reference values using the Exponential Mass Fractionation Law, which is a powerful tool to detect drifts. The results show that the dominant bias comes from the isotope fractionation, that can be minimized using the TE method. Acquired data suggest the following absolute composition for the JNdi-1 reference standard: 142 Nd/ 144 Nd = 1.13950(47) 143 Nd/ 144 Nd = 0.51163(30), 145 Nd/ 144 Nd = 0.34876(17), 146 Nd/ 144 Nd = 0.72322(65), 148 Nd/ 144 Nd = 0.24264(46) and 150 Nd/ 144 Nd = 0.23789(68) (k = 2). These values suggest the need to revisit the agreed upon reference values when Nd absolute isotopic composition is required. The conditions of the HPLC separation were also optimized to obtain purified fractions of Nd, Am and Cm in one experiment using a cation exchange column. Separations were achieved on the LUNA SCX column and using 2-Hydroxy-MethylButyric Acid (HMB) as eluent, introduced in gradient mode. A difference below 0.03 % was observed between data obtained with separation and without separation. Compared to previous work that required three separations using two different HPLC conditions, improvements were made in terms of both duration and amount of radioactive effluents. The methodology was then successfully applied to irradiated discs coming from MARIOS and DIAMINO analytical irradiation.
Fichier principal
Vignette du fichier
Publi_Nd_emfl.pdf (1.23 Mo) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

cea-03470782 , version 1 (08-12-2021)

Identifiers

Cite

Alexandre Quemet, Mathilde Angenieux, Alexandre Ruas. Nd, Am and Cm isotopic measurement after simultaneous separation in transmutation irradiated samples. Journal of Analytical Atomic Spectrometry, 2021, 36 (8), pp.1758-1767. ⟨10.1039/D1JA00165E⟩. ⟨cea-03470782⟩

Collections

CEA DEN DEN-MARCO
17 View
34 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More