Characterization of a medical interface

Abstract : The medical interface studied in this paper is an haptic interface. These interfaces are robotic devices intended to enhance the user's immersion in virtual environments through the stimulation of the haptic sense. Usually, they consist of an articulated mechanical structure which introduces distortion between the operator and the explored world. In order to assess the quality of the devices, it must be identified. This paper deals with this issue and introduces the characterization of the medical interface. Each 3 degrees of freedom (DOFs) branch uses a parallelogram and double parallelogram loop. The characterization is based on the inverse model and least squares method.
Document type :
Conference papers
Complete list of metadata

https://hal-cea.archives-ouvertes.fr/cea-03254586
Contributor : Catherine Bidard Connect in order to contact the contributor
Submitted on : Tuesday, June 8, 2021 - 11:31:38 PM
Last modification on : Tuesday, September 21, 2021 - 4:12:15 PM
Long-term archiving on: : Thursday, September 9, 2021 - 8:38:55 PM

File

Janot&al2007b.pdf
Files produced by the author(s)

Identifiers

Collections

Citation

A. Janot, C. Bidard, M. Gautier, F. Gosselin, D. Keller, et al.. Characterization of a medical interface. 2007 IEEE International Symposium on Industrial Electronics, Jun 2007, Vigo, Spain. pp.2071-2076, ⟨10.1109/ISIE.2007.4374927⟩. ⟨cea-03254586⟩