Design and development of a portable beta spectrometer for 90Sr measurement in contaminated matrices - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Access content directly
Journal Articles Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Year : 2020

Design and development of a portable beta spectrometer for 90Sr measurement in contaminated matrices

Abstract

Determining the nature and activity of radionuclides is an important task in the nuclear industry. Pure β- emitters are hard to characterize because the mean free path of electrons in dense matter is very short. Most measurement techniques are therefore based on destructive laboratory analyses. This article presents a non-destructive approach based on a portable β- spectrometer, designed to provide qualitative and quantitative information on pure β- emitters, notably 90Sr. Building on existing methods focused on the measurement of 90Sr activity in natural soil contaminated by the Chernobyl accident, the aim of this project is to develop a detector for the radiological characterization of different types of contaminated matrices, in particular the contaminated concrete structures typically found in nuclear facilities. A measurement device equipped with an EJ200 plastic scintillator was designed using Monte Carlo simulations with the MCNP6 and PENELOPE calculation codes. The energy calibration and the response of the detector were determined using experimental measurements and MCNP simulations of laboratory configurations of standard β- sources. These data were used to validate the model of the detector, as well as to determine calibration factors by numerical simulation for various on-site measurement configurations. The device was then used to characterize samples of sand from a decommissioning site in France (Fontenay-aux-Roses). The resulting 90Sr activities are within experimental uncertainties of those obtained using destructive measurements. These results are promising for wider applications on nuclear decommissioning sites.
Fichier principal
Vignette du fichier
S016890021931424X.pdf (1.25 Mo) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

cea-02927603 , version 1 (07-03-2022)

Licence

Attribution - NonCommercial

Identifiers

Cite

Julien Venara, Mehdi Ben Mosbah, Charly Mahe, Julien Astier, Susanna Adera, et al.. Design and development of a portable beta spectrometer for 90Sr measurement in contaminated matrices. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020, 953, pp.163081. ⟨10.1016/j.nima.2019.163081⟩. ⟨cea-02927603⟩
95 View
36 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More