Skip to Main content Skip to Navigation
Journal articles

Evaluation of PENFAST – A fast Monte Carlo code for dose calculations in photon and electron radiotherapy treatment planning

Bouchra Habib 1 Bénédicte Poumarede 1 François Tola 2 Jean Barthe 2
1 LM2S - Laboratoire Modélisation et Simulation de Systèmes
DM2I - Département Métrologie Instrumentation & Information : DRT/LIST/DM2I
2 LCAE - Laboratoire Capteurs et Architectures Electroniques
DM2I - Département Métrologie Instrumentation & Information : DRT/LIST/DM2I
Abstract : The aim of the present study is to demonstrate the potential of accelerated dose calculations, using the fast Monte Carlo (MC) code referred to as PENFAST, rather than the conventional MC code PENELOPE, without losing accuracy in the computed dose. For this purpose, experimental measurements of dose distributions in homogeneous and inhomogeneous phantoms were compared with simulated results using both PENELOPE and PENFAST. The simulations and experiments were performed using a Saturne 43 linac operated at 12 MV (photons), and at 18 MeV (electrons). Pre-calculated phase space files (PSFs) were used as input data to both the PENELOPE and PENFAST dose simulations. Since depth–dose and dose profile comparisons between simulations and measurements in water were found to be in good agreement (within ±1% to 1 mm), the PSF calculation is considered to have been validated. In addition, measured dose distributions were compared to simulated results in a set of clinically relevant, inhomogeneous phantoms, consisting of lung and bone heterogeneities in a water tank. In general, the PENFAST results agree to within a 1% to 1 mm difference with those produced by PENELOPE, and to within a 2% to 2 mm difference with measured values. Our study thus provides a pre-clinical validation of the PENFAST code. It also demonstrates that PENFAST provides accurate results for both photon and electron beams, equivalent to those obtained with PENELOPE. CPU time comparisons between both MC codes show that PENFAST is generally about 9–21 times faster than PENELOPE.
Complete list of metadatas

Cited literature [32 references]  Display  Hide  Download

https://hal-cea.archives-ouvertes.fr/cea-02542712
Contributor : Marie-France Robbe <>
Submitted on : Thursday, April 30, 2020 - 3:42:19 PM
Last modification on : Monday, May 4, 2020 - 9:38:40 AM

File

article_BouchraHabib_PhysicaMe...
Files produced by the author(s)

Identifiers

Collections

Citation

Bouchra Habib, Bénédicte Poumarede, François Tola, Jean Barthe. Evaluation of PENFAST – A fast Monte Carlo code for dose calculations in photon and electron radiotherapy treatment planning. Physica Medica, Elsevier, 2010, 26 (1), pp.17-25. ⟨10.1016/j.ejmp.2009.03.002⟩. ⟨cea-02542712⟩

Share

Metrics

Record views

72

Files downloads

73