Using gamma spectrometry indicators to detect and quantify fission products changes in irradiated fuel - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Access content directly
Conference Papers Year : 2015

Using gamma spectrometry indicators to detect and quantify fission products changes in irradiated fuel

Abstract

A new analysis method based on gamma scanning of fission products on irradiated rods is presented. Indicators calculated from this method can be used for the qualitative treatment and comparison of irradiated rods from PWR, SFR or and MTR. Differences in the behavior of fission products (FP) can thus be quantified. Phenomena such as migration or geometrical changes in pellets should thus benefit from these accurate, yet quickly and easily achievable results.
Fichier principal
Vignette du fichier
201500001363.pdf (573.55 Ko) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

cea-02509255 , version 1 (16-03-2020)

Identifiers

Cite

T. Martella, L. Loubet. Using gamma spectrometry indicators to detect and quantify fission products changes in irradiated fuel. ANIMMA 2015 - 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Apr 2015, Lisbonne, Portugal. ⟨10.1109/ANIMMA.2015.7465497⟩. ⟨cea-02509255⟩

Collections

CEA DEN
17 View
69 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More