Simulation of the VVER-1000 pump start-up experiment in the OECD/DOE/CEA V1000CT benchmark by the FLICA4/CRONOS2 coupled code system - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Accéder directement au contenu
Article Dans Une Revue Progress in Nuclear Energy Année : 2006

Simulation of the VVER-1000 pump start-up experiment in the OECD/DOE/CEA V1000CT benchmark by the FLICA4/CRONOS2 coupled code system

Résumé

In the framework of joint effort between the Nuclear Energy Agency (NEA) of OECD, the United States Departement of Energy (US DOE), and the Commissariat a l-Energie Atomique (CEA), France a coupled 3-D thermal hydraulics-neutron Kinetics benchmark was defined. The overall objective of OECD-NEA V1000CT reactivity transients where mixing phenomena (mass flow and temperature) in the reactor pressure vessel are complex. Original data from the Kosloduy-6 Nuclear Power Plant are available for the validation of computer codes one experiment of pump start-up (VT1000CT-2). The CEA presented results for the V1000CT-1 Exercise 2 using a coupling of FLICA4(3)and CRONOS2(2) via the coupling tool ISAS(4). The FLICA4-CRONOS2 VVER-1000 model is based on the data available in the benchmark specifications. this paper sensitivity studies and presents the CEA results for V1000CT-1 Exercise 2 as Well as a comparaison sith expereimental results at hot Power Steady State (HP SS)
Fichier principal
Vignette du fichier
200600005016.pdf (242.85 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

cea-02356018 , version 1 (09-12-2019)

Identifiants

Citer

Sylvie Aniel-Buchheit. Simulation of the VVER-1000 pump start-up experiment in the OECD/DOE/CEA V1000CT benchmark by the FLICA4/CRONOS2 coupled code system. Progress in Nuclear Energy, 2006, 48 (8), pp.773-789. ⟨10.1016/j.pnucene.2006.06.006⟩. ⟨cea-02356018⟩

Collections

CEA DEN ISAS
73 Consultations
150 Téléchargements

Altmetric

Partager