Clinical advantages of 3.0 T MRI over 1.5 T. European journal of radiology, vol.65, pp.2-14, 2008. ,
Imaging artifacts at 3.0T, Journal of Magnetic Resonance Imaging, vol.24, issue.4, pp.735-746, 2006. ,
DOI : 10.1002/jmri.20698
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/jmri.20698
Parallel transmission for ultrahigh-field imaging, NMR in Biomedicine, vol.29, issue.9, pp.1145-1161, 2016. ,
DOI : 10.1002/nbm.3313
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/nbm.3313
Clinical liver MRI at 3.0 Tesla using parallel RF transmission with patient-adaptive B1 shimming, Proc. Intl. Soc. Mag. Reson. Med, vol.17, p.119, 2009. ,
Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction, Magnetic Resonance in Medicine, vol.76, issue.6, pp.1951-1956, 2015. ,
Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion, Journal of Magnetic Resonance Imaging, vol.27, issue.6, pp.1443-1447, 2008. ,
B1+ homogenization at 7T using an innovative meta-atom, In: Proc. Intl. Soc. Mag. Reson. Med, vol.24, p.3531, 2016. ,
Method for controlling a magnetic resonance system, 2010. ,
Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses. Magnetic Resonance in Medicine, vol.67, pp.1303-1315, 2012. ,
DOI : 10.1002/mrm.23118
URL : https://hal.archives-ouvertes.fr/hal-00827673
B1 artifact reduction in abdominal DCE-MRI using kT-points: First clinical assessment of dynamic RF shimming at 3T, J Magn Reson Imaging, vol.47, issue.6, pp.1562-1571, 2018. ,
Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity, Magnetic Resonance in Medicine, vol.55, issue.4, pp.719-724, 2006. ,
DOI : 10.1002/mrm.20840
URL : https://deepblue.lib.umich.edu/bitstream/2027.42/49297/1/1181_ftp.pdf
Advanced three-dimensional tailored RF pulse for signal recovery in T2*-weighted functional magnetic resonance imaging, Magnetic Resonance in Medicine, vol.56, issue.5, pp.1050-1059, 2006. ,
DOI : 10.1002/mrm.21048
Small-tip-angle spokes pulse design using interleaved greedy and local optimization methods. Magnetic resonance in medicine, vol.68, pp.1553-1562, 2012. ,
DOI : 10.1002/mrm.24165
URL : http://europepmc.org/articles/pmc3703849?pdf=render
Mitigating transmit B1 inhomogeneity in the liver at 7T using multispoke parallel transmit RF pulse design, Quantitative Imaging in Medicine and Surgery, vol.4, issue.1, pp.4-10, 2014. ,
kT-points: Short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume, Magnetic Resonance in Medicine, vol.67, issue.1, pp.72-80, 2012. ,
DOI : 10.1002/mrm.22978
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.22978
Method and apparatus for compensating for B1 inhomogeneity in magnetic resonance imaging by nonselective tailored RF pulses. Patent WO2011128847A1, 2011. ,
, Transmit SENSE. Magnetic Resonance in Medicine, vol.49, issue.1, pp.144-150, 2003.
Parallel excitation with an array of transmit coils, Magnetic Resonance in Medicine, vol.51, issue.4, pp.775-784, 2004. ,
DOI : 10.1002/mrm.20011
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.20011
Reduced B1-inhomogeneities in breast MRI using optimized RF excitation, Proc. Intl. Soc ,
, Mag. Reson. Med, vol.16, p.2726, 2008.
Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7T, NeuroImage, vol.62, issue.3, pp.2140-2150, 2012. ,
Subject-and resource-specific monitoring and proactive management of parallel radiofrequency transmission, Magnetic Resonance in Medicine, vol.76, issue.1, pp.20-31, 2015. ,
Universal pulses: A new concept for calibration-free parallel transmission. Magnetic Resonance in Medicine, vol.77, pp.635-643, 2017. ,
URL : https://hal.archives-ouvertes.fr/hal-02103499
Homogeneous non-selective and slice-selective paralleltransmit excitations at 7 Tesla with universal pulses: A validation study on two commercial RF coils, PLOS ONE, vol.12, issue.8, p.183562, 2017. ,
Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T. Magnetic Resonance in Medicine, vol.80, pp.53-65, 2018. ,
Whole-brain 3D FLAIR at 7T using direct signal control, Magnetic Resonance in Medicine, vol.80, issue.4, pp.1533-1545, 2018. ,
A single-channel universal SPINS pulse for calibration-free homogeneous excitation without PTX, Proc. Intl. Soc. Mag. Reson. Med, vol.25, p.390, 2017. ,
Grissom William A. Machine learning RF shimming: Prediction by iteratively projected ridge regression, Magnetic Resonance in Medicine, vol.80, issue.5, pp.1871-1881, 2018. ,
Optimisation of parallel transmission radiofrequency pulses using neural networks, In: Proc. Intl. Soc. Mag. Reson ,
, , vol.26, p.3388, 2018.
Body MR imaging: Sequences we use and why, Appl Radiol, vol.38, issue.5, pp.7-12, 2009. ,
Optimal Acquisition Delay for Dynamic Contrast-Enhanced MRI of ,
, American Journal of Roentgenology, vol.192, issue.3, pp.686-692, 2009.
Magnetic resonance imaging: Review of imaging techniques and overview of liver imaging, World Journal of Radiology, vol.2, issue.8, pp.309-322, 2010. ,
Joint design of kT-points trajectories and RF pulses under explicit SAR and power constraints in the large flip angle regime, Journal of Magnetic Resonance, vol.261, pp.181-189, 2015. ,
kT-Points Pulse Design at 7T: Optimization of Pulse and Sub-Pulse Durations, Magnetic Resonance Materials in Physics, vol.29, pp.247-400, 2016. ,
Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels, Magnetic Resonance in Medicine, vol.59, issue.4, pp.908-915, 2008. ,
On variant strategies to solve the magnitude least squares optimization problem in parallel transmission pulse design and under strict SAR and power constraints, IEEE Transactions on Medical Imaging, vol.33, issue.3, pp.739-748, 2014. ,
URL : https://hal.archives-ouvertes.fr/hal-00858823
Fast Hierarchical, Agglomerative Clustering Routines for R and Python, Journal of Statistical Software, vol.53, issue.9, pp.1-18, 2013. ,
Local specific absorption rate control for parallel transmission by virtual observation points, Magnetic Resonance in Medicine, vol.66, issue.5, pp.1468-1476, 2011. ,
Gender differences in fat metabolism, Current Opinion in Clinical Nutrition & Metabolic Care, vol.4, issue.6, p.499, 2001. ,
The effect of sex, age and race on estimating percentage body fat from body mass index: The Heritage Family Study, International journal of obesity, vol.26, issue.6, p.789, 2002. ,
, NEMA PS 3 Supplement 23 Structured Reporting, The National Electrical Manufacturers Association. Digital Imaging and Communication in Medicine (DICOM), 1997.
Method and magnetic resonance system for adjustment of the field strength of RF pulses. Patent US20070145975A1, 2009. ,
Scikit-learn: Machine learning in Python, Journal of machine learning research, vol.12, pp.2825-2830, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00650905
Extremely randomized trees, Machine Learning, vol.63, issue.1, pp.3-42, 2006. ,
URL : https://hal.archives-ouvertes.fr/hal-00341932
Support-vector networks, Machine Learning, vol.20, issue.3, pp.273-297, 1995. ,
Probability estimates for multi-class classification by pairwise coupling, Journal of Machine Learning Research, vol.5, pp.975-1005, 2004. ,
SciPy: Open source scientific tools for Python, 2001. ,
Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression, Journal of Magnetic Resonance Imaging, vol.36, issue.2, pp.483-491, 2012. ,
A few useful things to know about machine learning, Communications of the ACM, vol.55, issue.10, p.78, 2012. ,
3D T 2-weighted imaging at 7T using dynamic kT-points on single-transmit MRI systems ,
, Magnetic Resonance Materials in Physics, Biology and Medicine, vol.29, issue.3, pp.347-358, 2016.
Paralleltransmission-enabled three-dimensional T2-weighted imaging of the human brain at 7 Tesla: 3D T2-Weighted Brain Imaging at 7T. Magnetic Resonance in Medicine, vol.73, pp.2195-2203, 2015. ,
B1 artifact reduction in abdominal DCE-MRI using kT-points: First clinical assessment of dynamic RF shimming at 3T, Journal of Magnetic Resonance Imaging, vol.47, issue.6, pp.1562-1571, 2018. ,