D. A. Laude, R. W. Lee, and C. L. Wilkins, Analytical Applications of a Recycled Flow Nuclear Magnetic Resonance System: Signal Enhancement of Slowly Relaxing Nuclei, Anal. Chem, vol.57, issue.7, pp.1281-1286, 1985.

H. H. Fischer, M. Seiler, T. S. Ertl, U. Eberhardinger, H. Bertagnolli et al., Quantification Studies in Continuous-Flow 13C Nuclear Magnetic Resonance Spectroscopy by Use of Immobilized Paramagnetic Relaxation Agents, J. Phys. Chem. B, issue.20, pp.4879-4886, 2003.

A. Causier, G. Carret, C. Boutin, T. Berthelot, and P. Berthault, 3D-Printed System Optimizing Dissolution of Hyperpolarized Gaseous Species for Micro-Sized NMR, Lab. Chip, vol.15, issue.9, pp.2049-2054, 2015.
URL : https://hal.archives-ouvertes.fr/hal-01156568

G. Carret, T. Berthelot, and P. Berthault, Enhancing NMR of Nonrelaxing Species Using a Controlled Flow Motion and a Miniaturized Circuit, Anal. Chem, vol.89, issue.5, pp.2995-3000, 2017.
URL : https://hal.archives-ouvertes.fr/cea-01449824

F. D. Doty, Probe Design and Construction
DOI : 10.1002/9780470034590.emrstm0414.pub2

D. I. Hoult and R. E. Richards, The Signal-to-Noise Ratio of the Nuclear Magnetic Resonance Experiment, J. Magn. Reson, vol.24, pp.71-85, 1976.

X. Wei, Z. Wang, and H. Dai, A Critical Review of Wireless Power Transfer via Strongly Coupled Magnetic Resonances. Energies, vol.7, pp.4316-4341, 2014.
DOI : 10.3390/en7074316

URL : http://www.mdpi.com/1996-1073/7/7/4316/pdf

T. Wang, L. Ciobanu, X. Zhang, and A. Webb, Inductively Coupled RF Coil Design for Simultaneous Microimaging of Multiple Samples, Conc. Magn. Reson. B, vol.33, issue.4, pp.236-243, 2008.
DOI : 10.1002/cmr.b.20122

URL : https://hal.archives-ouvertes.fr/cea-00334258

J. Ginefri, A. Rubin, M. Tatoulian, M. Woytasik, F. Boumezbeur et al., Implanted, InductivelyCoupled Radiofrequency Coils Fabricated on Flexible Polymeric Material : Application to in Vivo Rat Brain MRI at 7T, J. Magn. Reson, vol.224, pp.61-70, 2012.
DOI : 10.1016/j.jmr.2012.09.003

J. A. Tang and A. Jerschow, ) Utz, M.; Monazami, R. Nuclear Magnetic Resonance in Microfluidic Environments Using Inductively Coupled Radiofrequency Resonators, J. Magn. Reson, vol.198, issue.10, pp.132-136, 2009.

U. Ludwig, A. Eisenbeiss, C. Scheifele, K. Nelson, M. Bock et al., High-Resolution, High-Sensitivity NMR of Nanolitre Anisotropic Samples by Coil Spinning, Dental MRI Using Wireless Intraoral Coils. Sci. Rep, vol.447, issue.13, pp.694-708, 2007.

J. Mispelter, M. Lupu, and A. Briguet, ) Hoult, D. i.; Tomanek, B. Use of Mutually Inductive Coupling in Probe Design, Conc. Magn. Reson, vol.1, issue.15, pp.262-285, 2002.

J. Jacquinot and D. Sakellariou, ) Raad, A.; Darrasse, L. Optimization of NMR Receiver Bandwidth by Inductive Coupling, Conc. Magn. Reson. Part A, vol.38, issue.2, pp.55-65, 1992.

M. Khajeh, M. A. Bernstein, and G. A. Morris, A Simple Flowcell for Reaction Monitoring by NMR, Magn. Reson. Chem, issue.7, pp.516-522, 2010.
DOI : 10.1002/mrc.2610