Parameters influencing focalization spot in time reversal of acoustic waves - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Accéder directement au contenu
Communication Dans Un Congrès Année : 2015

Parameters influencing focalization spot in time reversal of acoustic waves

Résumé

Time reversal is an approach that can be used to focus acoustic waves in a particular location on a surface, allowing a multitouch tactile feedback interaction. The spatial resolution in this case depends on several parameters, such as geometrical parameters, frequency used and material properties, described by the Lamb wave theory. This paper highlights the impact of frequency, geometrical parameters such as plate thickness and transducer's surface on the focused spot dimensions. In this paper a study of the influence of the plate's thickness and the frequency bandwidth used in the focusing process is presented. It is also shown that the dimension of the piezoelectric diaphragms used has little influence on the spatial resolution. Resonant behavior of the plate and its implication on focus point dimension and focalization contrast were investigated.
Fichier non déposé

Dates et versions

cea-01841680 , version 1 (17-07-2018)

Identifiants

Citer

H. Zophoniasson, C. Bolzmacher, M. Hafez. Parameters influencing focalization spot in time reversal of acoustic waves. Proc. SPIE 9517, Smart Sensors, Actuators, and MEMS VII; and Cyber Physical Systems, 2015, Barcelona, Spain. ⟨10.1117/12.2178963⟩. ⟨cea-01841680⟩