Measurement of the mass concentration of flowing powder by fast X-ray CT - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Accéder directement au contenu
Article Dans Une Revue Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms Année : 2014

Measurement of the mass concentration of flowing powder by fast X-ray CT

Résumé

Estimating the mass concentration of granular substances in movement is of interest for industrial processes. In our specific application, a powder is transferred through a pipe to a reaction container and the objective is to measure the mass concentration at different cross section levels inside the container so that a spatial distribution can be estimated in dynamic conditions, i.e. powder flow. X-ray computed tomography (CT) is a non-invasive and non-destructive technique answering the requirements of our problem. A specific mechanical setup was built and because of space and mechanical constraints a special acquisition geometry was used, which implied the adaptation of the CT reconstruction algorithm.
Fichier non déposé

Dates et versions

cea-01834542 , version 1 (10-07-2018)

Identifiants

Citer

Marius Costin, Alexandre Vabre, Laurent Moch. Measurement of the mass concentration of flowing powder by fast X-ray CT. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2014, 324, pp.124 - 126. ⟨10.1016/j.nimb.2013.10.050⟩. ⟨cea-01834542⟩