Measurement of partial L fluorescence yields of bismuth using synchrotron radiation - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Accéder directement au contenu
Article Dans Une Revue Applied Radiation and Isotopes Année : 2016

Measurement of partial L fluorescence yields of bismuth using synchrotron radiation

Résumé

Tunable monochromatic photon radiation was used to measure transmission of a bismuth target in the energy range from 7 keV to 20 keV. Partial L fluorescence yields of bismuth were obtained by combining measurement of the fluorescence induced by photoionization of the bismuth target and X-rays from the radioactive decay of Pb-210. Several photon energies have been used to successively ionize the L subshells, which allowed detailed analysis of the rearrangement spectra and determination of the X-ray relative intensities of the L-1, L-2 and L-3 series.
Fichier non déposé

Dates et versions

cea-01833250 , version 1 (09-07-2018)

Identifiants

Citer

Yves Ménesguen, Bruno Boyer, Matias Rodrigues, Marie-Christine Lépy. Measurement of partial L fluorescence yields of bismuth using synchrotron radiation. Applied Radiation and Isotopes, 2016, 109, pp.133 - 138. ⟨10.1016/j.apradiso.2015.11.081⟩. ⟨cea-01833250⟩
51 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More