J. Seuntjens and D. S. , Photon absorbed dose standards Metrologia, vol.46, p.39, 2009.

S. Domen, A sealed water calorimeter for measuring absorbed dose, J. Res. Natl Inst. Stand. Technol, vol.99, p.121, 1994.

J. Seuntjens, C. Ross, N. Klassen, and K. Shortt, A status report on the NRC sealed water calorimeter NRC Report, 1999.

J. Medin, C. Ross, G. Stucki, N. Klassen, and J. Seuntjens, Commissioning of an NRC-type sealed water calorimeter at METAS using 60 Co ? -rays, Phys. Med. Biol, vol.49, p.4073, 2004.

C. Kessler, P. Allisy-roberts, D. Burns, P. Roger, A. Krauss et al., Comparison of the standards for absorbed dose to water of the PTB and the BIPM for 60 Co gamma rays Metrologia, p.6005, 2006.

A. Krauss, The PTB water calorimeter for the absolute determination of absorbed dose to water in 60 Co radiation, Metrologia, vol.43, p.259, 2006.

A. Krauss and R. Kapsch, Calorimetric determination of k Q factors for NE 2561 and NE 2571 ionization chambers in 5 cm × 5 cm and 10 cm × 10 cm radiotherapy beams of 8 MV and 16 MV photons, Phys. Med. Biol, vol.52, p.6243, 2007.

A. Krauss and R. Kapsch, Calorimetric determination of k Q factors for NE 2561 and NE 2571 ionization chambers in 5 cm × 5 cm and 10 cm × 10 cm radiotherapy beams of 8 MV and 16 MV photons, Phys. Med. Biol, vol.53, p.1151, 2008.

C. Kessler, P. Allisy-roberts, D. Burns, P. Roger, L. Prez et al., Comparison of the standards for absorbed dose to water of the VSL and the BIPM for 60 Co gamma rays Metrologia, vol.46, p.6009, 2009.

C. Kessler, D. Burns, A. Mccaffrey, J. Mcewen, M. Ross et al., Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60 Co gamma rays Metrologia, p.6016, 2010.

J. Witzani, K. Duftschmid, S. Ch, and A. Leitner, A graphite absorbed dose calorimeter in the quasi-isothermal mode of operation Metrologia, vol.20, pp.73-82, 1984.

V. Berlyand, Y. Bregadze, and S. Tsuriev, Working standard for unit of absorbed dose of photon ionizing radiation in water Izmer, p.51, 1986.

A. Dusautoy, The UK primary standard calorimeter for photon-beam absorbed dose measurement, Phys. Med. Biol, vol.41, p.137, 1996.

A. Guerra, R. Laitano, and M. Pimpinella, Characteristics of the absorbed dose to water standards at ENEA, Phys. Med. Biol, vol.41, p.657, 1996.

J. E. Lye, D. Butler, R. Franich, P. Harty, C. Oliver et al., Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60 Co radiation Radiat, Prot. Dosim, vol.155, p.100, 2013.

C. Kessler, P. Allisy-roberts, D. Burns, A. Guerra, R. Laitano et al., Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co gamma rays Metrologia, p.6002, 2010.

C. Kessler, P. Allisy-roberts, A. Steurer, A. Baumgartner, W. Tiefenboeck et al., Comparison of the standards for absorbed dose to water of the BEV Austria and the BIPM for 60 Co gamma rays Metrologia, p.6017, 2010.

A. Kessler, C. Burns, D. Berlyand, V. Berlyand, and A. , Comparison of the standards for absorbed dose to water of the VNIIFTRI and the BIPM for 60 Co ? -rays Metrologia, vol.47, p.6003, 2010.

C. Kessler, P. Allisy-roberts, D. Burns, P. Roger, Y. Morishita et al., Comparison of the standards for absorbed dose to water of the NMIJ and the BIPM for 60 Co ? -ray, Metrologia, vol.48, p.6008, 2011.

Y. Morishita, M. Kato, N. Takata, T. Kurosawa, T. Tanaka et al., A standard for absorbed dose rate to water in a 60 Co field using a graphite calorimeter at the National Metrology Institute of Japan Radiat, Prot. Dosim, vol.154, p.331, 2013.

J. Pearce, D. Shipley, and D. S. , Transfer of the UK absorbed dose primary standard for photon beams from the research linac to the clinical linac at NPL Metrologia, vol.48, p.365, 2011.

C. Kessler, P. Allisy, D. Burns, D. S. Manning, and J. , Comparison of the standards for absorbed dose to water of the NPL (UK) and the BIPM for 60 Co ? rays Metrologia, p.6008, 2012.

C. Kessler, D. Burns, A. Butler, D. , L. J. Webb et al., Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60 Co ? rays Metrologia, p.6009, 2012.

S. Picard, D. Burns, and P. Roger, Construction of an absorbed dose graphite calorimeter Rapport, 2009.

J. Daures and A. Ostrowsky, New constant-temperature operating mode for graphite calorimeter at LNE-LNHB, Phys. Med. Biol, vol.50, p.4035, 2005.

J. Daures, B. Chauvenet, and A. Ostrowsky, State-of-the-art of calorimetry at, LPRI Proc. NPL Calorimetry Workshop, 1994.

J. Daures, A. Ostrowsky, P. Gross, J. Jeannot, and J. Gouriou, Calorimetry for absorbed dose measurements at BNM-LNHB Proc. NPL Workshop on Recent Advances in Calorimetric Absorbed dose Standards, 2000.

B. Chauvenet, D. Baltès, and F. Delaunay, Comparison of graphite-to-water absorbed dose transfers for 60 Co photon beams using ionometry and Fricke dosimetry, Phys. Med. Biol, vol.42, p.2053, 1997.

A. Burns, D. Kessler, C. Delaunay, F. , and L. E. , Comparison of the standards for absorbed dose to water of the BNM-LNHB and the BIPM for 60 Co ? -rays, vol.42, p.6006, 2005.

K. Shortt, C. Ross, J. Seuntjens, F. Delaunay, A. Ostrowsky et al., Comparison of dosimetric standards of Canada and France for photons at 60 Co and higher energies, Phys. Med. Biol, vol.46, p.2119, 2001.

A. Ostrowsky and J. Daures, The construction of the graphite calorimeter GR-9, 2008.

J. Daures, A. Ostrowsky, and B. Rapp, Small section graphite calorimeter (GR-10) at LNE-LNHB for measurements in small beams for IMRT Metrologia, vol.49, p.174, 2012.

B. Rapp, A. Ostrowsky, and J. Daures, The LNE-LNHB water calorimeter: measurements in a 60 Co beam Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS) 2010 (Vienna), vol.1, p.67, 2011.

F. Delaunay, J. Gouriou, L. Roy, M. Ostrowsky, A. Sommier et al., Comparison of absorbed dose to water units for Co-60 and high-energy x-rays between PTB and LNE-LNHB Metrologia, vol.49, p.203, 2012.

J. Daures and A. Ostrowsky, Test of the new GR-9 graphite calorimeter. Comparison with GR-8 Workshop on Absorbed dose and Air Kerma Primary Standards, 2007.

I. Kawrakow, D. Rogers, and . The, EGSnrc code system: Monte Carlo simulation of electron and photon transport NRCC Report PIRS-701 (EGSnrc v4-r2-2-5, 2006.

D. Rogers, I. Kawrakow, J. Seuntjens, B. Walters, M. R-b et al., NRC User codes for EGSnrc NRCC Report, 2005.

D. Rogers, B. Walters, and K. Users, Manual NRCC Report PIRS-509revK, 2006.

F. Salvat, J. Fernandez-varea, and J. Sempau, PENELOPE-2006: a code system for Monte Carlo Simulation of electron and photon transport Workshop Proc, pp.4-7, 2006.

F. Tola, B. Poumarède, B. Habib, and M. Gmar, Optimization of Monte Carlo codes PENELOPE 2006 and PENFAST by parallelization and reduction variance implementation 2nd European Workshop on Monte Carlo Treatment Planning, 2009.

K. Bush, S. Zavgorodni, and W. A. Beckham, Azimuthal particle redistribution for the reduction of latent phase-space variance in Monte Carlo simulations, Phys. Med. Biol, vol.52, p.4345, 2007.

, International Commission on Radiation Units and Measurements, vol.37, 1984.

J. Mazurier, Adaptation du code de Monte Carlo PENELOPE pour la métrologie de la dose absorbée: caractérisation des faisceaux de photons X de hauté energie et calcul de facteurs de correction de dosimètres de référence Report CEA-R-5879, 1999.

F. Salvat, J. Fernandez-varea, and J. Sempau, PENELOPE-a code system for Monte Carlo simulation of electron and photon transport, Workshop Proc, pp.7-10, 2003.

B. Walters, K. I. , and R. , , 2006.

, DOSXYZnrc Users Manual NRCC Report PIRS-794(revB), 2006.

L. Blazy-aubignac, Contrôle qualité des systèmes de planification dosimétrique des traitements en radiothérapie externe au moyen du code Monte Carlo PENELOPE, 2007.

J. Motz, H. Olsen, and H. Koch, Rev. Mod. Phys, vol.41, p.581, 1969.

S. Seltzer and M. Berger, Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons, Nucl. Instrum. Methods Phys. Res. B, vol.12, p.95, 1985.

S. Seltzer and M. Berger, Bremsstrahlung energy spectra from electrons with kinetic energy from 1 keV to 10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z = 1-100 At. Data Nucl. Data Tables, vol.35, p.345, 1986.

J. Mazurier, F. Salvat, B. Chauvenet, and J. Barthe, Simulation of photon beams from a Saturne 43 accelerator using the code PENELOPE, Phys. Med. XV, vol.3, 1999.

S. Picard, D. Burns, P. Roger, P. Allisy-roberts, M. Mcewen et al., Comparison of the standards for absorbed dose to water of the NRC and the BIPM for accelerator photon beams Metrologia, vol.47, p.6025, 2010.

, Recommended data by the Decay Data Evaluation Project www

P. Andreo, Absorbed dose beam quality factors for the dosimetry of high-energy photon beams, Phys. Med. Biol, vol.37, p.2189, 1992.

C. Ma and N. , Dose conversion and wall correction factors for Fricke dosimetry in high-energy photon beams: analytical model and Monte Carlo calculations, Phys. Med. Biol, vol.38, p.93, 1993.

C. Ross, N. Klassen, and K. Shortt, The development of a standard based on water calorimetry for the absorbed dose to water Proc. NPL Calorimetry Workshop, 1994.

, Absorbed dose Determination in External Beam Radiotherapy International Atomic Energy Agency Vienna, Technical Report Series, issue.398, 2000.

B. Muir and R. , , 2010.

, Monte Carlo calculations of k Q , the beam quality conversion factor, Med. Phys, vol.37, p.5939

J. Wulff, J. Heverhagen, and K. Zink, Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams, Phys. Med. Biol, vol.53, p.2823, 2008.

J. Wulff, J. Heverhagen, K. Zink, and I. Kawrakow, Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors, Phys. Med. Biol, vol.55, p.4481, 2010.

H. Palmans, W. Mondelaers, and H. Thierens, Absorbed dose beam quality correction factors k Q for the NE 2571 chamber in a 5 MV and a 10 MV photon beams, Phys. Med. Biol, vol.44, p.647, 1999.

J. Medin, C. Ross, N. Klassen, H. Palmans, G. E. Grindborg et al., Experimental determination of beam quality factors, k Q , for two types of farmer chamber in a 10 MV photon and a 175 MeV proton beam, Phys. Med. Biol, vol.51, p.1503, 2006.

M. Mcewen, Measurement of ionization chamber absorbed dose k Q factors in megavoltage photon beams, Med. Phys, vol.37, p.2179, 2010.

C. Kessler, D. Burns, D. , F. Donois, and M. , Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation Metrologia, p.6019, 2013.

S. Picard, D. Burns, P. Roger, P. Allisy-roberts, R. Kapsch et al., Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the PTB, Germany and the BIPM for accelerator photon beams Metrologia, vol.48, p.6020, 2011.
URL : https://hal.archives-ouvertes.fr/cea-01816359

S. Picard, D. Burns, P. Roger, F. Delaunay, J. Gouriou et al., RI(I)-K6 of the standards for absorbed dose to water of the LNE-LNHB, France and the BIPM in accelerator photon beams Metrologia, vol.50, p.6015, 2013.
URL : https://hal.archives-ouvertes.fr/cea-01816359

S. Picard, D. Burns, P. Roger, F. Bateman, R. Tosh et al., RI(I)-K6 of the standards for absorbed dose to water of the NIST, USA and the BIPM in accelerator photon beams, Key comparison BIPM, vol.50, p.6004, 2013.

S. Picard, D. Burns, P. Roger, P. Harty, G. Ramanathan et al., Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the ARPANSA, Australia and the BIPM in accelerator photon beams Metrologia, vol.51, p.6006, 2014.
URL : https://hal.archives-ouvertes.fr/cea-01816359