Design and experimental evaluation of an infrared instrumentation for haptic interfaces - CEA - Commissariat à l’énergie atomique et aux énergies alternatives Accéder directement au contenu
Communication Dans Un Congrès Année : 2017

Design and experimental evaluation of an infrared instrumentation for haptic interfaces

Résumé

This paper presents the design and experimental evaluation of the end-effector of a dexterous encounter type haptic interface aimed at allowing natural interactions with digital mockups in Virtual Reality. This end-effector has two purposes: first, it should be able to precisely measure the 6D position and orientation of a fingertip remotely without equipping the user with any marker on the skin or nail. Second, it should serve as contact surface when force feedback is required. Therefore, we make use of 9 proximity sensors, 8 of which are placed around the finger in two planes, the last one being in front of it. Our results show that, after calibration, this configuration effectively allows measuring the configuration of a mock-up representative of the finger with a good precision for various positions and orientations.
Fichier non déposé

Dates et versions

cea-01831836 , version 1 (06-07-2018)

Identifiants

Citer

Amélie Chabrier, F. Gonzalez, F. Gosselin, Wael Bachta. Design and experimental evaluation of an infrared instrumentation for haptic interfaces. 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), May 2017, Turin, Italy. ⟨10.1109/I2MTC.2017.7969778⟩. ⟨cea-01831836⟩
55 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More