Skip to Main content Skip to Navigation
Conference papers

Performance of ADONIS-LYNX system for burn-up measurement applications at AREVA NC la Hague reprocessing plant

Abstract : This work deals with the last measurement campaign done at the AREVA NC La Hague reprocessing plant with the new industrial ADONIS system called ADONIS LYNX. In this paper we briefly explain the ADONIS bimodal Kalman smoother. Next, we present the experimental set-up as well as the industrial approach for the ADONIS system. Results from measurement campaign are then discussed. Some ways of improvement are also explained.
Document type :
Conference papers
Complete list of metadatas

https://hal-cea.archives-ouvertes.fr/cea-01822357
Contributor : Léna Le Roy <>
Submitted on : Monday, June 25, 2018 - 7:58:57 AM
Last modification on : Monday, February 10, 2020 - 6:13:45 PM

Identifiers

Collections

CEA | DRT | LIST | DM2I

Citation

E. Barat, S. Normand, T. Dautremer, J. Lefevre, C. Herman, et al.. Performance of ADONIS-LYNX system for burn-up measurement applications at AREVA NC la Hague reprocessing plant. 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA), Jun 2013, Marseille, France. ⟨10.1109/ANIMMA.2013.6727894⟩. ⟨cea-01822357⟩

Share

Metrics

Record views

119