Abstract : A synthetic single crystal diamond sample has been prepared with graphitic in bulk electrodes by laser induced graphitisation of diamond. A geometry with an array of electrodes has been fabricated to demonstrate the functionality of a “3D diamond detector” for ionising radiation. The detection capability has been studied with synchrotron radiation.
https://hal-cea.archives-ouvertes.fr/cea-01815567 Contributor : Bruno SavelliConnect in order to contact the contributor Submitted on : Thursday, June 14, 2018 - 11:53:58 AM Last modification on : Saturday, June 25, 2022 - 9:11:28 PM
Alexander Oh, Benoît Caylar, Michal Pomorski, Thorsten Wengler. A novel detector with graphitic electrodes in CVD diamond. Diamond and Related Materials, Elsevier, 2013, 38, pp.9 - 13. ⟨10.1016/j.diamond.2013.06.003⟩. ⟨cea-01815567⟩