H. Benmakhlouf, J. Sempau, and P. Andreo, Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

, Med Phys, vol.41, p.41711, 2014.

H. Bouchard, Y. Kamio, H. Palmans, J. Seuntjens, and D. S. , Detector dose response in megavoltage small photon beams. I. Theoretical concepts, Med Phys, vol.42, pp.6033-6080, 2015.

A. Scott, S. Kumar, A. E. Nahum, and J. D. Fenwick, Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields, Phys Med Biol, vol.57, pp.4461-76, 2012.

R. Alfonso, P. Andreo, R. Capote, S. Huq, M. Kilby et al., A new formalism for reference dosimetry of small and nonstandard fields, Med Phys, vol.35, pp.5179-86, 2008.

G. Azangwe, P. Grochowska, D. Georg, J. Izewska, J. Hopfgartner et al., Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurement for small radiotherapy beams, Med Phys, vol.41, p.72103, 2014.

D. Czarnecki and K. Zink, Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields, Phys Med Biol, vol.58, pp.2431-2475, 2013.

P. Francescon, W. Kilby, J. M. Noll, L. Masi, N. Satariano et al., Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors, Phys Med Biol, vol.62, pp.1076-95, 2017.

W. Lechner, H. Palmans, L. Sölkner, P. Grochowska, and G. D. , Detector comparison for small field output factor measurements in flattening filter free photon beams, Radiother Oncol, vol.109, pp.356-60, 2013.

L. Masi, S. Russo, P. Francescon, R. Doro, M. C. Frassanito et al., CyberKnife beam output factor measurements: a multi-site and multidetector study, Phys Med, vol.32, pp.1647-1656, 2016.

O. 'brien, D. J. León-vintró, L. Mcclean, and B. , Small field detector correction factors for silicon-diode and diamond detectors with circular 6 MV fields derived using both empirical and numerical methods, Med Phys, vol.43, pp.411-434, 2016.

P. Papaconstadopoulos, F. Tessier, and J. Seuntjens, On the correction, perturbation and modification of small field detectors in relative dosimetry, Phys Med Biol, vol.59, pp.5937-52, 2014.

A. Ralston, M. Tyler, P. Liu, D. Mckenzie, and N. Suchowerska, Over-response of synthetic microDiamond detectors in small radiation fields, Phys Med Biol, vol.59, pp.5873-81, 2014.

T. Underwood, B. C. Rowland, R. Ferrand, and L. Vieillevigne, Application of the Exradin W1 scintillator to determine Ediode 60017 and microDiamond 60019 correction factors for relative dosimetry within small MV and FFF fields, Phys Med Biol, vol.60, pp.6669-83, 2015.

C. Huet, C. Moignier, V. Barraux, C. Loiseau, K. Sebe-mercier et al., Study of commercial detector responses in non-equilibrium small photon fields of a 1000 MU/min CyberKnife system, Phys Med, vol.32, pp.818-843, 2016.

P. Andreo, H. Palmans, M. Marteinsdóttir, H. Benmakhlouf, and Å. Carlsson-tedgren, On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry, Phys Med Biol, vol.61, pp.1-10, 2016.

M. Marinelli, G. Prestopino, C. Verona, and G. Verona-rinati, Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume, Med Phys, vol.43, p.5205, 2016.

P. H. Charles, G. Cranmer-sargison, D. I. Thwaites, S. B. Crowe, T. Kairn et al., A practical and theoretical definition of very small field size for radiotherapy output factor measurements, Med Phys, vol.41, pp.41707-41708, 2014.

, Dosimetry in diagnostic radiology: an International Code of Practice, IAEA Technical Report Series, vol.457, 2007.

A. Djouguela, D. Harder, R. Kollhoff, A. Ruhmann, K. C. Willborn et al., The dosearea product, a new parameter for the dosimetry of narrow photon beams, Z Med Phys, vol.16, pp.217-244, 2006.

S. Duane, F. Graber, and R. Thomas, International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry; Application of Dose Area Product and DAP Ratio to Dosimetry in IMRT and Small Field External Beam Radiotherapy, 2010.

L. Roy, M. Dufreneix, S. Daures, J. Delaunay, F. Gouriou et al., Establishment of dosimetric references in terms of dose-area product for small sizes MV X-ray beams, Phys Med, vol.31, issue.S2, pp.52-55, 2015.

F. Sánchez-doblado, G. H. Hartmann, J. Pena, J. V. Roselló, G. Russiello et al., A new method for output factor determination in MLC shaped narrow beams, Phys Med, vol.23, pp.58-66, 2007.

M. Pimpinella, D. Coste, V. Guerra, A. S. Silvi, L. Petrucci et al., Measurements of Dose.area-product ratio in small radiotherapy photon beams using two types of large-area plane-parallel ionization chambers, Phys Med, vol.31, issue.s2, p.53, 2015.

T. Underwood, H. C. Winter, M. A. Hill, and J. D. Fenwick, Detector density and small field dosimetry: integral versus point dose measurement schemes, vol.40, pp.82102-82103, 2013.
DOI : 10.1118/1.4812687

URL : https://aapm.onlinelibrary.wiley.com/doi/pdf/10.1118/1.4812687

S. Dufreneix, A. Ostrowsky, L. Roy, M. Sommier, L. Gouriou et al., Using a dose-area product for absolute measurements in small fields: a feasibility study, Phys Med Biol, vol.61, pp.650-62, 2016.
DOI : 10.1088/0031-9155/61/2/650

URL : https://hal.archives-ouvertes.fr/hal-01864082

S. Dufreneix, J. Bordy, J. Daures, F. Delaunay, and A. Ostrowsky, Construction of a large graphite calorimeter for measurements in small fields used in radiotherapy. 16th International Congress of Metrology, 2013.

P. Andreo, D. T. Burns, K. Hohlfeld, M. S. Huq, T. Kanai et al., Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water, IAEA Technical Report Series, vol.398, 2000.

D. Rogers, B. A. Faddegon, G. X. Ding, C. Ma, J. We et al., BEAM: a Monte Carlo code to simulate radiotherapy treatment units, Med Phys, vol.22, pp.503-507, 1995.
DOI : 10.1118/1.597552

I. Kawrakow, E. Mainegra-hing, D. Rogers, F. Tessier, and B. Walter, The EGSnrc Code System: Monte Carlo simulation of electron and photon transport, 2013.

P. Francescon, S. Cora, and C. Cavedon, Total scatter factors of small beams: a multidetector and Monte Carlo study, Med Phys, vol.35, pp.504-517, 2008.
DOI : 10.1118/1.2828195

URL : http://europepmc.org/articles/pmc3899064?pdf=render

C. Ma, R. Dwo-;-e)-reva, and C. Ottawa, BEAMDP as a General-Purpose Utility, 2013.

D. Rogers, B. Walter, and I. Kawrakow, BEAMnrc user manual. NRC Report PIRS509(A) revL. Ottawa, Canada: National Research Council of Canada (NRC), 2013.

I. Kawrakow, D. Rogers, and B. Walter, Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting, Med Phys, vol.31, pp.2883-98, 2004.
DOI : 10.1118/1.1788912

D. Rogers, I. Kawrakow, J. P. Seuntjens, and B. Walter, NRCC user codes for EGSnrc, 2013.

F. Salvat, J. M. Fernandez-varea, and J. Sempau, A code system for Monte Carlo Simulation of Electron and Photon Transport, Workshop Proc, 2006.

F. Tola, B. Poumarede, B. Habib, and M. Gmar, Optimization of Monte Carlo codes PENELOPE 2006 and PENFAST by parallelization and reduction variance implementation; Second European Workshop on Monte Carlo Treatment Planning, Workshop MCTP, 2009.

M. Constantin, J. Perl, T. Losasso, A. Salop, D. Whittum et al., Modeling the truebeam linac using a CAD to Geant4 geometry implementation: dose and IAEAcompliant phase space calculations, Med Phys, vol.38, pp.4018-4042, 2011.
DOI : 10.1118/1.3598439

S. Dufreneix, Etablissement de références dosimétriques dans les faisceaux de rayons × de hautes énergies et de très petites sections (< 1 cm 2 ) pour la radiothérapie

, Français. < NNT: 2014PA112416 >. < tel-01127240 >, 2014.

J. W. Boag, Ionization chambers, The dosimetry of ionizing radiation, vol.2, pp.169-243, 1987.

, Evaluation of measurement data-Guide to the expression of uncertainty in measurement JCGM, JCGM, pp.1-134, 2008.

K. Eklund and A. Ahnesj?, Fast modelling of spectra and stopping power ratio using differentiated fluence pencil kernels, Phys Med Biol, vol.52, pp.4231-4278, 2008.

F. Araki, Monte Carlo study of a CyberKnife stereotactic radiosurgery system, Med Phys, vol.33, pp.2955-63, 2006.

F. Sánchez-doblado, P. Andreo, R. Capote, A. Leal, M. Perucha et al., Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams, Phys Med Biol, vol.48, pp.2081-99, 2003.

F. Verhaegen, I. J. Das, and H. Palmans, Monte Carlo dosimetry study of a 6 MV stereotactic radiosurgery unit, Phys Med Biol, vol.43, pp.2755-68, 1998.

P. Andreo and A. Brahme, Stopping power data for high-energy photon beams, Phys Med Biol, vol.31, pp.839-58, 1986.

G. Ponti, The role of medium size facilities in the HPC ecosystem: the case of the new CRESCO4 cluster integrated in the ENEAGRID infrastructure, Proceedings of the International Conference on High Performance Computing and Simulation (HPCS), pp.1030-1063, 2014.

J. Daures, A. Ostrowsky, and B. Rapp, Small section graphite calorimeter (GR-10) at LNELNHB for measurements in small beams for IMRT, Metrologia, vol.49, pp.174-182, 2012.