Abstract : We show that a significant improvement in the sensitivity of a Huxley–Holmes design for a small angle x-ray scattering camera is obtained by separating the mirror and the monochromator. The design of the camera involves a long x-ray mirror close to a point x-ray source associated with a curved focusing crystal located close to the sample. The sample area is located at half the distance between the source and detector planes. Diffuse scattering produced by the mirror is not incident on the focusing crystal, thus reducing the background signal. Complete elimination of hard x rays allows precise calibration and hence absolute determination of sample cross section by means of a semitransparent beam stop. In pinhole geometry, the flux corresponds to a ;107 photons/s through the sample, collimated to 1022 Å21 in q range. This allows determination of scattered intensities on the order of 1023 cm21, corresponding to the scattering related to isothermal compressibility of less than 0.1 mm of pure water. As a reference sample, the widely used Lupolen™, a semicrystalline polymer, is calibrated. The high-q limit (q'4.5 nm21) of a porous calcite sample can be used as a secondary standard for specific area determination of solid/solid or solid–liquid dispersions.
Complete list of metadatas

Cited literature [5 references]  Display  Hide  Download

https://hal-cea.archives-ouvertes.fr/cea-00268837
Contributor : Olivier Taché <>
Submitted on : Tuesday, April 1, 2008 - 3:12:07 PM
Last modification on : Monday, February 10, 2020 - 6:12:47 PM
Long-term archiving on: : Friday, May 21, 2010 - 1:05:27 AM

File

rsi.pdf
Publisher files allowed on an open archive

Identifiers

Citation

Thomas Zemb, Olivier Taché, Frédéric Né, Olivier Spalla. Improving sensitivity of a small angle x-ray scattering camera with pinhole collimation using separated optical elements. Review of Scientific Instruments, American Institute of Physics, 2001, 74 (4), pp.2456. ⟨10.1063/1.1556954⟩. ⟨cea-00268837⟩

Share

Metrics

Record views

244

Files downloads

562